{"description":"Trending threats, MITRE ATT\u0026CK coverage, and detection metadata. Fed continuously.","feed_url":"https://feed.craftedsignal.io/tags/health-data/feed.json","home_page_url":"https://feed.craftedsignal.io/","items":[{"_cs_actors":[],"_cs_cpes":[],"_cs_cves":[],"_cs_exploited":false,"_cs_has_poc":false,"_cs_poc_references":[],"_cs_products":["Mira Hormone Monitor","Mira Android App"],"_cs_severities":["critical"],"_cs_tags":["medical-device","vulnerability","ics","health-data"],"_cs_type":"advisory","_cs_vendors":["Quanovate Tech Inc."],"content_html":"\u003cp\u003eResearchers have identified eight critical vulnerabilities (CVE-2026-66875, CVE-2026-66098, CVE-2026-67558, CVE-2026-67568, CVE-2026-68067, CVE-2026-66340, CVE-2026-64934, CVE-2026-66832) within the Mira Hormone Monitor firmware version 1.7.1.47 and the associated Mira Android application version 4.5.15.4. The vulnerabilities stem from a lack of secure authentication for critical device functions, use of hard-coded credentials, and improper validation of Bluetooth Low Energy (BLE) peripheral identity.\u003c/p\u003e\n\u003cp\u003eDefenders should note that these flaws allow unauthenticated attackers within BLE range (10-30 meters) to rebind devices, intercept cleartext hormone data, and disrupt fertility monitoring services. Furthermore, cloud-facing vulnerabilities in the associated Android APK permit unauthorized access to reproductive health profiles, potentially leading to the destruction or forgery of sensitive clinical data. The breadth of these flaws, particularly those enabling remote cloud-based exploitation and local BLE spoofing, presents a significant risk to the privacy and integrity of user healthcare information.\u003c/p\u003e\n\u003ch2 id=\"impact\"\u003eImpact\u003c/h2\u003e\n\u003cp\u003eSuccessful exploitation allows for unauthorized access to sensitive reproductive health profiles, the ability to manipulate historical clinical trends, disclosure of session tokens, and complete loss of account control. These vulnerabilities affect the Healthcare and Public Health sector worldwide, directly impacting user safety and the reliability of fertility monitoring workflows.\u003c/p\u003e\n\u003ch2 id=\"recommendation\"\u003eRecommendation\u003c/h2\u003e\n\u003cul\u003e\n\u003cli\u003eImmediately update the Mira Android application to version 4.5.18 or higher.\u003c/li\u003e\n\u003cli\u003eEnsure the Mira Monitor hardware firmware is updated to version 01.07.01.53, which is triggered automatically via the updated Android application.\u003c/li\u003e\n\u003cli\u003eReview network access logs for unusual patterns of interaction with Mira cloud API endpoints if the application was utilized in a high-threat environment.\u003c/li\u003e\n\u003cli\u003eMonitor for anomalous BLE advertisement names that attempt to masquerade as legitimate Mira devices to facilitate peripheral spoofing.\u003c/li\u003e\n\u003c/ul\u003e\n","date_modified":"2026-08-11T17:37:00Z","date_published":"2026-08-11T17:37:00Z","id":"https://feed.craftedsignal.io/briefs/2026-08-mira-hormone-monitor-vulns/","summary":"Multiple critical vulnerabilities in Quanovate Tech Inc. Mira Hormone Monitor firmware and Android application enable unauthenticated remote access, health data tampering, and credential theft via BLE and cloud-based attack vectors.","title":"Multiple Vulnerabilities in Mira Hormone Monitor and Android App","url":"https://feed.craftedsignal.io/briefs/2026-08-mira-hormone-monitor-vulns/"}],"language":"en","title":"CraftedSignal Threat Feed - Health-Data","version":"https://jsonfeed.org/version/1.1"}