{"description":"Trending threats, MITRE ATT\u0026CK coverage, and detection metadata — refreshed continuously.","feed_url":"https://feed.craftedsignal.io/tags/cve-2026-7694/","home_page_url":"https://feed.craftedsignal.io/","items":[{"_cs_actors":[],"_cs_cves":[{"cvss":7.3,"id":"CVE-2026-7694"}],"_cs_exploited":false,"_cs_products":["ECEMS Enterprise Microgrid Energy Efficiency Management System 1.3.0"],"_cs_severities":["high"],"_cs_tags":["sql-injection","cve-2026-7694","webserver"],"_cs_type":"advisory","_cs_vendors":["Acrel Electrical"],"content_html":"\u003cp\u003eAcrel Electrical\u0026rsquo;s ECEMS Enterprise Microgrid Energy Efficiency Management System version 1.3.0 is vulnerable to SQL injection. The vulnerability resides in the \u003ccode\u003e/SubstationWEBV2/main/elecMaxMinAvgValue\u003c/code\u003e file, where manipulation of the \u003ccode\u003efCircuitids\u003c/code\u003e argument allows for the injection of arbitrary SQL commands. The vulnerability, identified as CVE-2026-7694, can be exploited remotely without authentication, posing a significant risk to systems exposed to the network. The vendor was notified but did not respond, and a public exploit is available, increasing the likelihood of exploitation. This flaw allows attackers to potentially access, modify, or delete sensitive data within the ECEMS database.\u003c/p\u003e\n\u003ch2 id=\"attack-chain\"\u003eAttack Chain\u003c/h2\u003e\n\u003col\u003e\n\u003cli\u003eAttacker identifies an accessible instance of Acrel ECEMS 1.3.0.\u003c/li\u003e\n\u003cli\u003eAttacker crafts a malicious SQL payload designed to extract sensitive information or modify the database.\u003c/li\u003e\n\u003cli\u003eThe attacker sends a crafted HTTP request to \u003ccode\u003e/SubstationWEBV2/main/elecMaxMinAvgValue\u003c/code\u003e with the SQL payload embedded in the \u003ccode\u003efCircuitids\u003c/code\u003e parameter.\u003c/li\u003e\n\u003cli\u003eThe ECEMS application fails to properly sanitize the \u003ccode\u003efCircuitids\u003c/code\u003e input.\u003c/li\u003e\n\u003cli\u003eThe application executes the attacker-supplied SQL query against the database.\u003c/li\u003e\n\u003cli\u003eThe database server processes the malicious query, potentially returning sensitive data or executing harmful commands.\u003c/li\u003e\n\u003cli\u003eThe attacker receives the output of the injected SQL query.\u003c/li\u003e\n\u003cli\u003eThe attacker uses the extracted information for further malicious activities, such as data exfiltration, privilege escalation, or denial of service.\u003c/li\u003e\n\u003c/ol\u003e\n\u003ch2 id=\"impact\"\u003eImpact\u003c/h2\u003e\n\u003cp\u003eSuccessful exploitation of this SQL injection vulnerability could allow an attacker to read sensitive information from the ECEMS database, modify existing data, or even gain administrative access to the system. This could lead to the compromise of energy efficiency management data, potentially impacting grid stability and financial records. Given the lack of vendor response and the availability of a public exploit, organizations using the affected software are at high risk. The impact includes potential data breaches, system outages, and reputational damage.\u003c/p\u003e\n\u003ch2 id=\"recommendation\"\u003eRecommendation\u003c/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInspect web server logs for suspicious requests to \u003ccode\u003e/SubstationWEBV2/main/elecMaxMinAvgValue\u003c/code\u003e containing potentially malicious SQL syntax within the \u003ccode\u003efCircuitids\u003c/code\u003e parameter (see Sigma rule \u0026ldquo;Detect Acrel ECEMS SQL Injection Attempt\u0026rdquo;).\u003c/li\u003e\n\u003cli\u003eDeploy the Sigma rule \u0026ldquo;Detect SQL Injection Error Messages\u0026rdquo; to identify potential SQL injection attempts across all web applications.\u003c/li\u003e\n\u003cli\u003eApply input validation and sanitization to all user-supplied input, especially the \u003ccode\u003efCircuitids\u003c/code\u003e parameter in \u003ccode\u003e/SubstationWEBV2/main/elecMaxMinAvgValue\u003c/code\u003e, to prevent SQL injection.\u003c/li\u003e\n\u003cli\u003eConsider deploying a web application firewall (WAF) to filter out malicious requests targeting this vulnerability.\u003c/li\u003e\n\u003c/ul\u003e\n","date_modified":"2026-05-03T12:15:59Z","date_published":"2026-05-03T12:15:59Z","id":"/briefs/2026-05-acrel-sql-injection/","summary":"A SQL injection vulnerability in Acrel Electrical ECEMS Enterprise Microgrid Energy Efficiency Management System 1.3.0 allows remote attackers to execute arbitrary SQL commands by manipulating the 'fCircuitids' argument in the '/SubstationWEBV2/main/elecMaxMinAvgValue' file.","title":"Acrel ECEMS SQL Injection Vulnerability","url":"https://feed.craftedsignal.io/briefs/2026-05-acrel-sql-injection/"}],"language":"en","title":"CraftedSignal Threat Feed — Cve-2026-7694","version":"https://jsonfeed.org/version/1.1"}