{"description":"Trending threats, MITRE ATT\u0026CK coverage, and detection metadata — refreshed continuously.","feed_url":"https://feed.craftedsignal.io/tags/appsync/","home_page_url":"https://feed.craftedsignal.io/","items":[{"_cs_actors":[],"_cs_cves":[{"cvss":7.3,"id":"CVE-2026-22767"}],"_cs_exploited":false,"_cs_products":[],"_cs_severities":["medium"],"_cs_tags":["symlink","dell","appsync","privilege-escalation"],"_cs_type":"advisory","_cs_vendors":[],"content_html":"\u003cp\u003eDell AppSync version 4.6.0 contains a UNIX Symbolic Link (Symlink) Following vulnerability, identified as CVE-2026-22767. This vulnerability enables a low-privileged attacker with local access to exploit the system and potentially tamper with sensitive information. The vulnerability was disclosed on April 1, 2026. Defenders should be aware of the potential for local privilege escalation and information tampering due to this vulnerability. Addressing this vulnerability is critical to maintaining the integrity and confidentiality of data managed by Dell AppSync.\u003c/p\u003e\n\u003ch2 id=\"attack-chain\"\u003eAttack Chain\u003c/h2\u003e\n\u003col\u003e\n\u003cli\u003eAttacker gains local access to the system running Dell AppSync 4.6.0.\u003c/li\u003e\n\u003cli\u003eAttacker identifies a directory writable by low-privileged users where AppSync improperly handles symlinks.\u003c/li\u003e\n\u003cli\u003eAttacker creates a malicious symbolic link pointing to a sensitive system file (e.g., \u003ccode\u003e/etc/shadow\u003c/code\u003e, configuration files).\u003c/li\u003e\n\u003cli\u003eAppSync, while performing its normal operations, follows the symbolic link created by the attacker.\u003c/li\u003e\n\u003cli\u003eAppSync attempts to access or modify the target file through the symlink.\u003c/li\u003e\n\u003cli\u003eDue to insufficient permission checks, AppSync inappropriately overwrites, reads, or modifies the sensitive file.\u003c/li\u003e\n\u003cli\u003eAttacker leverages the modified sensitive file to escalate privileges or gain unauthorized access.\u003c/li\u003e\n\u003cli\u003eAttacker achieves the objective of information tampering by modifying application data.\u003c/li\u003e\n\u003c/ol\u003e\n\u003ch2 id=\"impact\"\u003eImpact\u003c/h2\u003e\n\u003cp\u003eSuccessful exploitation of CVE-2026-22767 can lead to information tampering on systems running Dell AppSync 4.6.0. A low-privileged attacker with local access could potentially modify system or application configurations, leading to unauthorized access or disruption of services. The impact includes potential data corruption, privilege escalation, and a compromise of the overall system security posture.\u003c/p\u003e\n\u003ch2 id=\"recommendation\"\u003eRecommendation\u003c/h2\u003e\n\u003cul\u003e\n\u003cli\u003eApply the security update provided by Dell as detailed in DSA-2026-163 to remediate CVE-2026-22767 (\u003ca href=\"https://www.dell.com/support/kbdoc/en-us/000446965/dsa-2026-163-security-update-for-dell-appsync-vulnerabilities\"\u003ehttps://www.dell.com/support/kbdoc/en-us/000446965/dsa-2026-163-security-update-for-dell-appsync-vulnerabilities\u003c/a\u003e).\u003c/li\u003e\n\u003cli\u003eImplement the \u0026ldquo;Detect Suspicious Symlink Creation\u0026rdquo; Sigma rule to identify potentially malicious symlink activity on systems running Dell AppSync.\u003c/li\u003e\n\u003cli\u003eMonitor file system events for unexpected modifications to sensitive files, particularly those targeted by symlinks, using the \u0026ldquo;Detect Sensitive File Tampering via Symlink\u0026rdquo; Sigma rule.\u003c/li\u003e\n\u003c/ul\u003e\n","date_modified":"2026-04-01T13:16:33Z","date_published":"2026-04-01T13:16:33Z","id":"/briefs/2026-04-dell-appsync-symlink/","summary":"Dell AppSync version 4.6.0 is vulnerable to a UNIX Symbolic Link (Symlink) Following vulnerability (CVE-2026-22767) that allows a low-privileged local attacker to tamper with information.","title":"Dell AppSync 4.6.0 UNIX Symbolic Link Following Vulnerability (CVE-2026-22767)","url":"https://feed.craftedsignal.io/briefs/2026-04-dell-appsync-symlink/"},{"_cs_actors":[],"_cs_cves":[{"cvss":7.3,"id":"CVE-2026-22768"}],"_cs_exploited":false,"_cs_products":[],"_cs_severities":["high"],"_cs_tags":["dell","appsync","privilege-escalation","cve-2026-22768"],"_cs_type":"advisory","_cs_vendors":[],"content_html":"\u003cp\u003eDell AppSync version 4.6.0 is vulnerable to an incorrect permission assignment issue. A local attacker with low privileges can exploit this vulnerability to escalate their privileges on the affected system. This vulnerability, identified as CVE-2026-22768, could allow an attacker to gain unauthorized access to sensitive data or execute arbitrary code with elevated privileges. Successful exploitation requires local access and user interaction (UI:R). This vulnerability poses a significant risk to organizations using the affected version of Dell AppSync, as it could lead to data breaches, system compromise, and other security incidents. Defenders should prioritize patching or mitigating this vulnerability to prevent potential exploitation.\u003c/p\u003e\n\u003ch2 id=\"attack-chain\"\u003eAttack Chain\u003c/h2\u003e\n\u003col\u003e\n\u003cli\u003eThe attacker gains initial local access to a system running Dell AppSync 4.6.0.\u003c/li\u003e\n\u003cli\u003eThe attacker identifies the critical resource with incorrect permission assignments (CWE-732).\u003c/li\u003e\n\u003cli\u003eThe attacker crafts a malicious input or action that triggers the vulnerable code path within AppSync. This requires some user interaction, such as clicking a link or opening a file.\u003c/li\u003e\n\u003cli\u003eDue to the incorrect permission assignments, the attacker is able to modify or access the critical resource.\u003c/li\u003e\n\u003cli\u003eThe attacker leverages the modified resource to execute arbitrary code or gain access to sensitive data.\u003c/li\u003e\n\u003cli\u003eThe attacker escalates privileges by exploiting the vulnerability.\u003c/li\u003e\n\u003cli\u003eThe attacker uses their elevated privileges to install malware, exfiltrate data, or perform other malicious activities.\u003c/li\u003e\n\u003c/ol\u003e\n\u003ch2 id=\"impact\"\u003eImpact\u003c/h2\u003e\n\u003cp\u003eSuccessful exploitation of this vulnerability allows a low-privileged local attacker to elevate their privileges to that of a system administrator. While the specific number of affected organizations is unknown, any organization using Dell AppSync 4.6.0 is potentially vulnerable. A successful attack could result in unauthorized access to sensitive data, system compromise, and potential data breaches. The CVSS v3.1 base score for this vulnerability is 7.3 (HIGH), reflecting the significant risk it poses.\u003c/p\u003e\n\u003ch2 id=\"recommendation\"\u003eRecommendation\u003c/h2\u003e\n\u003cul\u003e\n\u003cli\u003eApply the security update provided by Dell as detailed in DSA-2026-163 to patch CVE-2026-22768.\u003c/li\u003e\n\u003cli\u003eMonitor systems running Dell AppSync for suspicious activity indicative of privilege escalation attempts.\u003c/li\u003e\n\u003cli\u003eReview and harden permission assignments on critical resources within the Dell AppSync environment to prevent future vulnerabilities of this type (CWE-732).\u003c/li\u003e\n\u003c/ul\u003e\n","date_modified":"2026-04-01T13:16:33Z","date_published":"2026-04-01T13:16:33Z","id":"/briefs/2026-04-dell-appsync-privesc/","summary":"Dell AppSync version 4.6.0 contains an incorrect permission assignment vulnerability that allows a low-privileged attacker with local access to elevate privileges on the system.","title":"Dell AppSync 4.6.0 Incorrect Permission Assignment Vulnerability","url":"https://feed.craftedsignal.io/briefs/2026-04-dell-appsync-privesc/"}],"language":"en","title":"CraftedSignal Threat Feed — Appsync","version":"https://jsonfeed.org/version/1.1"}