<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:webfeeds="http://webfeeds.org/rss/1.0"><channel><title>IDRAC8 (&lt; 2.52.52.52) - CraftedSignal Threat Feed</title><link>https://feed.craftedsignal.io/products/idrac8--2.52.52.52/</link><description>Trending threats, MITRE ATT&amp;CK coverage, and detection metadata. Fed continuously.</description><generator>Hugo</generator><language>en</language><managingEditor>hello@craftedsignal.io</managingEditor><webMaster>hello@craftedsignal.io</webMaster><lastBuildDate>Sat, 12 Sep 2026 17:50:38 +0000</lastBuildDate><atom:link href="https://feed.craftedsignal.io/products/idrac8--2.52.52.52/feed.xml" rel="self" type="application/rss+xml"/><image><url>https://feed.craftedsignal.io/favicon-32x32.png</url><title>CraftedSignal Threat Feed</title><link>https://feed.craftedsignal.io/</link><width>32</width><height>32</height></image><webfeeds:icon>https://feed.craftedsignal.io/favicon.svg</webfeeds:icon><item><title>Remote Code Execution in Dell iDRAC7 and iDRAC8</title><link>https://feed.craftedsignal.io/briefs/2026-09-cve-2018-1207-idrac-rce/</link><pubDate>Sat, 12 Sep 2026 17:50:38 +0000</pubDate><author>hello@craftedsignal.io</author><guid isPermaLink="true">https://feed.craftedsignal.io/briefs/2026-09-cve-2018-1207-idrac-rce/</guid><description>CVE-2018-1207 allows unauthenticated attackers to achieve root-level remote code execution on Dell iDRAC7 and iDRAC8 firmware versions 2.52.52.52 and below via dynamic linker injection.</description><content:encoded><![CDATA[<p>Dell iDRAC7 and iDRAC8 firmware versions 2.52.52.52 and below are vulnerable to a critical remote code execution (RCE) flaw tracked as CVE-2018-1207. The vulnerability exists within the web management interface, which fails to sanitize input parameters, allowing an attacker to manipulate environment variables for the dynamic linker. By leveraging the <code>LD_DEBUG</code> and <code>LD_PRELOAD</code> variables, an attacker can force the iDRAC web server process to load a malicious shared object (<code>.so</code>) file. Exploitation grants the attacker full root-level control over the management controller. The recent publication of functional PoC exploit scripts significantly increases the risk for organizations running legacy Dell PowerEdge server hardware that has not been updated to the recommended firmware versions.</p>
<h2 id="attack-chain">Attack Chain</h2>
<ol>
<li>The attacker probes the target iDRAC web interface at <code>/cgi-bin/login</code> using the <code>LD_DEBUG=files</code> query parameter to confirm the device is vulnerable by observing debug output.</li>
<li>The attacker creates a malicious C payload designed to spawn a reverse shell.</li>
<li>The payload is cross-compiled for the SH4 architecture using <code>sh4-linux-gnu-gcc</code> to produce a malicious shared object (<code>.so</code>) file.</li>
<li>The attacker uploads the malicious library to the target device by sending a <code>POST</code> request to the <code>/cgi-bin/putfile</code> endpoint, which writes the file to <code>/tmp/sshpkauthupload.tmp</code>.</li>
<li>The attacker triggers execution by sending a <code>GET</code> request to <code>/cgi-bin/discover</code> with the <code>LD_PRELOAD</code> environment variable set to the path of the uploaded library (<code>/tmp/sshpkauthupload.tmp</code>).</li>
<li>The iDRAC dynamic linker loads the malicious library before the application initializes, triggering the <code>constructor</code> function within the library.</li>
<li>The injected code executes with root privileges, establishing a reverse shell connection back to the attacker-controlled listener.</li>
</ol>
<h2 id="impact">Impact</h2>
<p>Successful exploitation allows unauthenticated attackers to gain complete control over the iDRAC management controller. This leads to full system compromise, as the attacker can manipulate hardware power states, access stored data, exfiltrate credentials, and potentially pivot into the host operating system or the wider data center network. The vulnerability is highly exploitable, and the widespread use of iDRAC in enterprise environments makes this a significant risk for server infrastructure.</p>
<h2 id="recommendation">Recommendation</h2>
<p>Prioritize the identification of all internet-facing or vulnerable internal iDRAC interfaces.</p>
<ul>
<li>Patch all affected Dell iDRAC7 and iDRAC8 devices to firmware version 2.52.52.52 or later immediately.</li>
<li>Implement strict network segmentation to ensure iDRAC management interfaces are only accessible via trusted, restricted administrative networks.</li>
<li>Monitor web server access logs for unusual <code>POST</code> requests to <code>/cgi-bin/putfile</code> and <code>GET</code> requests containing <code>LD_DEBUG</code> or <code>LD_PRELOAD</code> query parameters.</li>
<li>Deploy the provided Sigma rule to detect attempts at exploiting the dynamic linker injection path.</li>
</ul>
]]></content:encoded><category domain="severity">critical</category><category domain="type">advisory</category><category>cve-2018-1207</category><category>rce</category><category>idrac</category><category>remote-code-execution</category><category>firmware-vulnerability</category></item></channel></rss>