{"description":"Trending threats, MITRE ATT\u0026CK coverage, and detection metadata. Fed continuously.","favicon":"https://feed.craftedsignal.io/favicon-32x32.png","feed_url":"https://feed.craftedsignal.io/cpes/cpe2.3ahitachienergytro600/feed.json","home_page_url":"https://feed.craftedsignal.io/","icon":"https://feed.craftedsignal.io/apple-touch-icon.png","items":[{"_cs_actors":[],"_cs_cpes":["cpe:2.3:a:hitachienergy:tro600:*:*:*:*:*:*:*:*"],"_cs_cves":[{"id":"CVE-2026-106087"},{"id":"CVE-2026-10756"}],"_cs_exploited":false,"_cs_has_poc":false,"_cs_poc_references":[],"_cs_products":["TRO600 (\u003c= 9.2.1.6)","TRO600 (\u003c= 9.1.1.0)"],"_cs_severities":["high"],"_cs_tags":["industrial-control-systems","energy","ics-advisory"],"_cs_type":"threat","_cs_vendors":["Hitachi Energy"],"content_html":"\u003cp\u003eHitachi Energy TRO600 series products contain two high-severity vulnerabilities. CVE-2026-10756 allows an authenticated attacker to bypass network restrictions and access services intended to be reachable only from localhost via port forwarding. CVE-2026-106087 allows an unauthenticated attacker to perform arbitrary file reads, potentially exposing sensitive configuration files and credentials. No evidence of in-the-wild exploitation was provided in the advisory.\u003c/p\u003e\n\u003ch2 id=\"impact\"\u003eImpact\u003c/h2\u003e\n\u003cp\u003eSuccessful exploitation may result in unauthorized access to sensitive functionality, disclosure of confidential information including password data, and availability impact on Industrial Control System (ICS) environments.\u003c/p\u003e\n\u003ch2 id=\"recommendation\"\u003eRecommendation\u003c/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUpdate TRO600 series devices to version 9.2.2.1 or 9.1.2.0 as applicable to remediate identified vulnerabilities.\u003c/li\u003e\n\u003cli\u003eMinimize network exposure for all control system devices by ensuring they are not directly accessible from the internet.\u003c/li\u003e\n\u003cli\u003eIsolate control system networks behind firewalls and utilize VPNs for remote access, ensuring VPN infrastructure is kept current.\u003c/li\u003e\n\u003cli\u003eImplement defense-in-depth strategies as outlined in CISA's ICS cybersecurity best practices.\u003c/li\u003e\n\u003c/ul\u003e\n","date_modified":"2026-10-29T23:07:35Z","date_published":"2026-10-29T23:07:35Z","id":"https://feed.craftedsignal.io/briefs/2026-10-hitachi-tro600/","summary":"Hitachi Energy TRO600 series products are vulnerable to unauthorized service access via network restriction bypass and unauthenticated arbitrary file read, potentially leading to credential exposure.","title":"Hitachi Energy TRO600 Series Vulnerabilities (CVE-2026-10756, CVE-2026-106087)","url":"https://feed.craftedsignal.io/briefs/2026-10-hitachi-tro600/"}],"language":"en","title":"CraftedSignal Threat Feed - Cpe:2.3:a:hitachienergy:tro600:*:*:*:*:*:*:*:*","version":"https://jsonfeed.org/version/1.1"}