Skip to content
Threat Feed
low advisory

Fidelis Network and Deception: Local Privilege Escalation (CVE-2022-0486)

Multiple Fidelis products are vulnerable to local privilege escalation due to insecure file permissions on binaries and scripts owned by the fidelis user, allowing for unauthorized root access via sudo.

CVE search metadata

CVE search record: CVE-2022-0486. Severity: medium. CVSS: 4.4. EPSS: 0.39%. KEV: no. Product: Fidelis CommandPost (< 9.4.5), Fidelis Collector (< 9.4.5), Fidelis Sensor (< 9.4.5), Fidelis Sandbox (< 9.4.5), Fidelis Deception (< 9.4.5). Brief: Fidelis Network and Deception: Local Privilege Escalation (CVE-2022-0486). Brief link: https://feed.craftedsignal.io/briefs/2026-10-fidelis-lpe/

Triage facts

Revision 1
Applicability
Fidelis CommandPost (< 9.4.5), Fidelis Collector (< 9.4.5) +3
Evidence
Unknown
Severity
Low
Action
Elevated
Sources
2 public sources
Freshness
Revision 1Oct 25, 10:42 UTC
Vulnerabilities
1 CVE
Source quality
A1Likely

CVE-2022-0486 encompasses a series of improper file permission vulnerabilities in Fidelis CommandPost, Collector, Sensor, and Sandbox components of Fidelis Network and Deception. The vulnerabilities exist because the 'fidelis' user holds sudo permissions to execute specific binaries and scripts that the user also owns. This allows a local attacker to modify the files, injecting arbitrary code or spawning shells to achieve root-level privilege escalation.

Attack Chain

  1. Attacker gains local command-line interface (CLI) access as the 'fidelis' user.
  2. Attacker identifies a vulnerable binary or script in the /FSS/ directory (e.g., /FSS/bin/shutdown.pl) that is owned by the 'fidelis' user.
  3. Attacker modifies the file permissions (e.g., chmod 700 or u+w) to allow write access.
  4. Attacker overwrites the content of the target script or binary with malicious code (e.g., executing /bin/sh).
  5. Attacker executes the modified file via sudo, providing a password if required by the sudoers configuration.
  6. The command executes with root privileges, granting the attacker full system control.

Impact

Successful exploitation grants a local, authenticated 'fidelis' user full root-level control over the affected Fidelis component.

Recommendation

  • Update all Fidelis CommandPost, Collector, Sensor, and Sandbox instances to version 9.4.5 or later immediately.
  • Disable shell/SSH access to Fidelis products after initial configuration to prevent local access vectors.
  • If patching is not immediately possible, restrict ownership of vulnerable files (e.g., /FSS/bin/shutdown.pl, /FSS/setup/cert_mgmt) to root:fidelis and limit group permissions to read and execute only.

Immediate actions

Patch Fidelis products to version 9.4.5 or later.

IT Operations 48h

Threat Hunt

Monitor for chmod modifications on files within the /FSS/ directory.

T1548.003 high high confidence hunt now

Data: Linux auditd logs or filesystem integrity monitoring

Monitor sudo execution of binaries within /FSS/ by the fidelis user.

T1548.003 high medium confidence hunt now

Data: sudoers log (auth.log / secure log)

Mitigations

Disable SSH/shell access to Fidelis CommandPost and Sensor instances.

immediate IT Operations

CVE-2022-0486