Fidelis Network and Deception: Local Privilege Escalation (CVE-2022-0486)
Multiple Fidelis products are vulnerable to local privilege escalation due to insecure file permissions on binaries and scripts owned by the fidelis user, allowing for unauthorized root access via sudo.
CVE search metadata
CVE search record: CVE-2022-0486. Severity: medium. CVSS: 4.4. EPSS: 0.39%. KEV: no. Product: Fidelis CommandPost (< 9.4.5), Fidelis Collector (< 9.4.5), Fidelis Sensor (< 9.4.5), Fidelis Sandbox (< 9.4.5), Fidelis Deception (< 9.4.5). Brief: Fidelis Network and Deception: Local Privilege Escalation (CVE-2022-0486). Brief link: https://feed.craftedsignal.io/briefs/2026-10-fidelis-lpe/
Triage facts
Revision 1- Applicability
- Fidelis CommandPost (< 9.4.5), Fidelis Collector (< 9.4.5) +3
- Evidence
- Unknown
- Severity
- Low
- Action
- Elevated
- Sources
- 2 public sources
- Freshness
- Revision 1Oct 25, 10:42 UTC
- Vulnerabilities
- 1 CVE
- Source quality
- A1Likely
CVE-2022-0486 encompasses a series of improper file permission vulnerabilities in Fidelis CommandPost, Collector, Sensor, and Sandbox components of Fidelis Network and Deception. The vulnerabilities exist because the 'fidelis' user holds sudo permissions to execute specific binaries and scripts that the user also owns. This allows a local attacker to modify the files, injecting arbitrary code or spawning shells to achieve root-level privilege escalation.
Attack Chain
- Attacker gains local command-line interface (CLI) access as the 'fidelis' user.
- Attacker identifies a vulnerable binary or script in the /FSS/ directory (e.g., /FSS/bin/shutdown.pl) that is owned by the 'fidelis' user.
- Attacker modifies the file permissions (e.g., chmod 700 or u+w) to allow write access.
- Attacker overwrites the content of the target script or binary with malicious code (e.g., executing /bin/sh).
- Attacker executes the modified file via sudo, providing a password if required by the sudoers configuration.
- The command executes with root privileges, granting the attacker full system control.
Impact
Successful exploitation grants a local, authenticated 'fidelis' user full root-level control over the affected Fidelis component.
Recommendation
- Update all Fidelis CommandPost, Collector, Sensor, and Sandbox instances to version 9.4.5 or later immediately.
- Disable shell/SSH access to Fidelis products after initial configuration to prevent local access vectors.
- If patching is not immediately possible, restrict ownership of vulnerable files (e.g., /FSS/bin/shutdown.pl, /FSS/setup/cert_mgmt) to root:fidelis and limit group permissions to read and execute only.
Immediate actions
Patch Fidelis products to version 9.4.5 or later.
Threat Hunt
Monitor for chmod modifications on files within the /FSS/ directory.
Data: Linux auditd logs or filesystem integrity monitoring
Monitor sudo execution of binaries within /FSS/ by the fidelis user.
Data: sudoers log (auth.log / secure log)
Mitigations
Disable SSH/shell access to Fidelis CommandPost and Sensor instances.