Skip to content
Threat Feed
high advisory

Solid Edge SE2026 Stack-Based Overflow Vulnerability (CVE-2026-44412)

A stack-based overflow vulnerability in Solid Edge SE2026 (versions prior to V226.0 Update 5) allows for arbitrary code execution via specially crafted PAR files.

A stack-based buffer overflow vulnerability, tracked as CVE-2026-44412, has been identified in Siemens Solid Edge SE2026. The vulnerability exists in all versions prior to V226.0 Update 5. This flaw stems from improper handling of specially crafted PAR files, potentially enabling an attacker to execute arbitrary code within the context of the affected process. Successful exploitation could lead to complete system compromise, data theft, or other malicious activities. Siemens has released an update to address this vulnerability. This vulnerability poses a significant risk to organizations utilizing affected versions of Solid Edge SE2026 for CAD and engineering design.

Attack Chain

  1. An attacker crafts a malicious PAR file specifically designed to trigger the stack-based buffer overflow.
  2. The attacker delivers the malicious PAR file to a target user, potentially through social engineering, email attachment, or a compromised website.
  3. The user opens the malicious PAR file using a vulnerable version of Solid Edge SE2026.
  4. Solid Edge SE2026 attempts to parse the PAR file.
  5. During the parsing process, the specially crafted data overflows the designated buffer on the stack.
  6. The overflow overwrites critical data, including the return address, on the stack.
  7. Upon function return, control is redirected to an attacker-controlled address.
  8. The attacker executes arbitrary code within the context of the Solid Edge SE2026 process, potentially gaining complete control over the system.

Impact

Successful exploitation of CVE-2026-44412 allows an attacker to execute arbitrary code on the targeted system. This can lead to a variety of detrimental outcomes, including data theft, system compromise, and the installation of malware. Given the use of Solid Edge SE2026 in industrial design and engineering, successful attacks could disrupt critical infrastructure, compromise sensitive intellectual property, and cause significant financial losses. The number of potential victims is substantial, encompassing all organizations utilizing vulnerable versions of Solid Edge SE2026.

Recommendation

  • Immediately update Solid Edge SE2026 to V226.0 Update 5 or later to patch CVE-2026-44412.
  • Deploy the Sigma rule “Detect Suspicious Solid Edge Process Execution” to identify potential exploitation attempts based on unusual process behavior.
  • Educate users about the risks of opening files from untrusted sources to mitigate social engineering attacks.
  • Monitor systems for unexpected process creations originating from Solid Edge SE2026, as this could indicate successful exploitation.

Detection coverage 2

Detect Suspicious Solid Edge Process Execution

high

Detects potentially malicious process execution originating from Solid Edge, indicating possible exploitation of CVE-2026-44412

sigma tactics: execution techniques: T1059.004 sources: process_creation, windows

Detect Solid Edge PAR File Opening

medium

Detects the opening of PAR files by Solid Edge, which could be related to the exploitation of CVE-2026-44412. Note: Requires file auditing.

sigma tactics: initial_access techniques: T1566 sources: file_event, windows

Detection queries are available on the platform. Get full rules →